run_test 224b "Don't panic on bulk IO failure"
+test_224c() { # LU-6441
+ [ $PARALLEL == "yes" ] && skip "skip parallel run" && return
+ local pages_per_rpc=$($LCTL get_param \
+ osc.*.max_pages_per_rpc)
+ local at_max=$(do_facet mgs "$LCTL get_param -n at_max")
+ local timeout=$(do_facet mgs "$LCTL get_param -n timeout")
+
+ $LCTL set_param -n osc.*.max_pages_per_rpc=1024
+ do_facet mgs "$LCTL conf_param $FSNAME.sys.at_max=0"
+ do_facet mgs "$LCTL conf_param $FSNAME.sys.timeout=5"
+
+ #define OBD_FAIL_PTLRPC_CLIENT_BULK_CB3 0x520
+ $LCTL set_param fail_loc=0x520
+ dd if=/dev/zero of=$DIR/$tfile bs=8MB count=1
+ sync
+ $LCTL set_param fail_loc=0
+
+ do_facet mgs "$LCTL conf_param $FSNAME.sys.at_max=" \
+ "$at_max"
+ do_facet mgs "$LCTL conf_param $FSNAME.sys.timeout=" \
+ "$timeout"
+ $LCTL set_param -n $pages_per_rpc
+}
+run_test 224c "Don't hang if one of md lost during large bulk RPC"
+
MDSSURVEY=${MDSSURVEY:-$(which mds-survey 2>/dev/null || true)}
test_225a () {
[ $PARALLEL == "yes" ] && skip "skip parallel run" && return