# 1 2.5 2.5 4 4 (min)"
[ "$SLOW" = "no" ] && EXCEPT_SLOW="17 26a 26b 50 51 57"
+[ $(facet_fstype $SINGLEMDS) = "zfs" ] &&
+# bug number for skipped test: LU-2194 LU-2547
+ ALWAYS_EXCEPT="$ALWAYS_EXCEPT 19b 24a"
+
build_test_filter
# Allow us to override the setup if we already have a mounted system by
local BEFORE=`date +%s`
local EVICT
- mount_client $DIR2
+ mount_client $DIR2 || error "failed to mount $DIR2"
- do_facet client mcreate $DIR/$tfile || return 1
- drop_ldlm_cancel "chmod 0777 $DIR2"
+ # cancel cached locks from OST to avoid eviction from it
+ cancel_lru_locks osc
+
+ do_facet client "stat $DIR > /dev/null" ||
+ error "failed to stat $DIR: $?"
+ drop_ldlm_cancel "chmod 0777 $DIR2" ||
+ error "failed to chmod $DIR2"
umount_client $DIR2
- do_facet client "munlink $DIR/$tfile"
# let the client reconnect
- sleep 5
+ client_reconnect
EVICT=$(do_facet client $LCTL get_param mdc.$FSNAME-MDT*.state | \
awk -F"[ [,]" '/EVICTED]$/ { if (mx<$4) {mx=$4;} } END { print mx }')
- [ ! -z "$EVICT" ] && [[ $EVICT -gt $BEFORE ]] || error "no eviction"
+ [ ! -z "$EVICT" ] && [[ $EVICT -gt $BEFORE ]] ||
+ (do_facet client $LCTL get_param mdc.$FSNAME-MDT*.state;
+ error "no eviction: $EVICT before:$BEFORE")
}
run_test 19a "test expired_lock_main on mds (2867)"
local BEFORE=`date +%s`
local EVICT
- mount_client $DIR2
+ mount_client $DIR2 || error "failed to mount $DIR2: $?"
- do_facet client $MULTIOP $DIR/$tfile Ow || return 1
- drop_ldlm_cancel $MULTIOP $DIR2/$tfile Ow
- umount_client $DIR2
- do_facet client munlink $DIR/$tfile
+ # cancel cached locks from MDT to avoid eviction from it
+ cancel_lru_locks mdc
+
+ do_facet client $MULTIOP $DIR/$tfile Ow ||
+ error "failed to run multiop: $?"
+ drop_ldlm_cancel $MULTIOP $DIR2/$tfile Ow ||
+ error "failed to ldlm_cancel: $?"
+
+ umount_client $DIR2 || error "failed to unmount $DIR2: $?"
+ do_facet client munlink $DIR/$tfile ||
+ error "failed to unlink $DIR/$tfile: $?"
# let the client reconnect
- sleep 5
+ client_reconnect
EVICT=$(do_facet client $LCTL get_param osc.$FSNAME-OST*.state | \
awk -F"[ [,]" '/EVICTED]$/ { if (mx<$4) {mx=$4;} } END { print mx }')
- [ ! -z "$EVICT" ] && [[ $EVICT -gt $BEFORE ]] || error "no eviction"
+ [ ! -z "$EVICT" ] && [[ $EVICT -gt $BEFORE ]] ||
+ (do_facet client $LCTL get_param osc.$FSNAME-OST*.state;
+ error "no eviction: $EVICT before:$BEFORE")
}
run_test 19b "test expired_lock_main on ost (2867)"
+test_19c() {
+ local BEFORE=`date +%s`
+
+ mount_client $DIR2
+ $LCTL set_param ldlm.namespaces.*.early_lock_cancel=0
+
+ mkdir -p $DIR1/$tfile
+ stat $DIR1/$tfile
+
+#define OBD_FAIL_PTLRPC_CANCEL_RESEND 0x516
+ do_facet mds $LCTL set_param fail_loc=0x80000516
+
+ touch $DIR2/$tfile/file1 &
+ PID1=$!
+ # let touch to get blocked on the server
+ sleep 2
+
+ wait $PID1
+ $LCTL set_param ldlm.namespaces.*.early_lock_cancel=1
+ umount_client $DIR2
+
+ # let the client reconnect
+ sleep 5
+ EVICT=$(do_facet client $LCTL get_param mdc.$FSNAME-MDT*.state |
+ awk -F"[ [,]" '/EVICTED]$/ { if (mx<$4) {mx=$4;} } END { print mx }')
+
+ [ -z "$EVICT" ] || [[ $EVICT -le $BEFORE ]] || error "eviction happened"
+}
+run_test 19c "check reconnect and lock resend do not trigger expired_lock_main"
+
test_20a() { # bug 2983 - ldlm_handle_enqueue cleanup
remote_ost_nodsh && skip "remote OST with nodsh" && return 0
test_24b() {
remote_ost_nodsh && skip "remote OST with nodsh" && return 0
- dmesg -c
+ dmesg -c > /dev/null
mkdir -p $DIR/$tdir
lfs setstripe $DIR/$tdir -s 0 -i 0 -c 1
cancel_lru_locks osc
lctl set_param fail_loc=0x0
client_reconnect
[ $rc1 -eq 0 -o $rc2 -eq 0 ] &&
- error_ignore "multiop didn't fail fsync: $rc1 or close: $rc2" || true
+ error_ignore 5494 "multiop didn't fail fsync: $rc1 or close: $rc2" ||
+ true
dmesg | grep "dirty page discard:" || \
error "no discarded dirty page found!"
# fail abort so client will be new again
fail_abort $SINGLEMDS
client_up || error "reconnect failed"
+ wait_osc_import_state $SINGLEMDS ost FULL
return 0
}
run_test 29a "error adding new clients doesn't cause LBUG (bug 22273)"
}
run_test 61 "Verify to not reuse orphan objects - bug 17025"
+# test_62 as seen it b2_1 please do not reuse test_62
+#test_62()
+#{
+# zconf_umount `hostname` $DIR
+# #define OBD_FAIL_PTLRPC_DELAY_IMP_FULL 0x516
+# lctl set_param fail_loc=0x516
+# mount_client $DIR
+#}
+#run_test 62 "Verify connection flags race - bug LU-1716"
+
check_cli_ir_state()
{
local NODE=${1:-$HOSTNAME}
return $rc
}
run_test 107 "drop reint reply, then restart MDT"
+
+test_110a () {
+ [ $MDSCOUNT -lt 2 ] && skip "needs >= 2 MDTs" && return 0
+ local remote_dir=$DIR/$tdir/remote_dir
+ local MDTIDX=1
+
+ mkdir -p $DIR/$tdir
+ drop_request "$LFS mkdir -i $MDTIDX $remote_dir" ||
+ error "lfs mkdir failed"
+ local diridx=$($GETSTRIPE -M $remote_dir)
+ [ $diridx -eq $MDTIDX ] || error "$diridx != $MDTIDX"
+
+ rm -rf $DIR/$tdir || error "rmdir failed"
+}
+run_test 110a "create remote directory: drop client req"
+
+test_110b () {
+ [ $MDSCOUNT -lt 2 ] && skip "needs >= 2 MDTs" && return 0
+ local remote_dir=$DIR/$tdir/remote_dir
+ local MDTIDX=1
+
+ mkdir -p $DIR/$tdir
+ drop_reint_reply "$LFS mkdir -i $MDTIDX $remote_dir" ||
+ error "lfs mkdir failed"
+
+ diridx=$($GETSTRIPE -M $remote_dir)
+ [ $diridx -eq $MDTIDX ] || error "$diridx != $MDTIDX"
+
+ rm -rf $DIR/$tdir || error "rmdir failed"
+}
+run_test 110b "create remote directory: drop Master rep"
+
+test_110c () {
+ [ $MDSCOUNT -lt 2 ] && skip "needs >= 2 MDTs" && return 0
+ local remote_dir=$DIR/$tdir/remote_dir
+ local MDTIDX=1
+
+ mkdir -p $DIR/$tdir
+ drop_update_reply $((MDTIDX + 1)) "$LFS mkdir -i $MDTIDX $remote_dir" ||
+ error "lfs mkdir failed"
+
+ diridx=$($GETSTRIPE -M $remote_dir)
+ [ $diridx -eq $MDTIDX ] || error "$diridx != $MDTIDX"
+
+ rm -rf $DIR/$tdir || error "rmdir failed"
+}
+run_test 110c "create remote directory: drop update rep on slave MDT"
+
+test_110d () {
+ [ $MDSCOUNT -lt 2 ] && skip "needs >= 2 MDTs" && return 0
+ local remote_dir=$DIR/$tdir/remote_dir
+ local MDTIDX=1
+
+ mkdir -p $DIR/$tdir
+ $LFS mkdir -i $MDTIDX $remote_dir || error "lfs mkdir failed"
+
+ drop_request "rm -rf $remote_dir" || error "rm remote dir failed"
+
+ rm -rf $DIR/$tdir || error "rmdir failed"
+
+ return 0
+}
+run_test 110d "remove remote directory: drop client req"
+
+test_110e () {
+ [ $MDSCOUNT -lt 2 ] && skip "needs >= 2 MDTs" && return 0
+ local remote_dir=$DIR/$tdir/remote_dir
+ local MDTIDX=1
+
+ mkdir -p $DIR/$tdir
+ $LFS mkdir -i $MDTIDX $remote_dir || error "lfs mkdir failed"
+ drop_reint_reply "rm -rf $remote_dir" || error "rm remote dir failed"
+
+ rm -rf $DIR/$tdir || error "rmdir failed"
+
+ return 0
+}
+run_test 110e "remove remote directory: drop master rep"
+
+test_110f () {
+ [ $MDSCOUNT -lt 2 ] && skip "needs >= 2 MDTs" && return 0
+ local remote_dir=$DIR/$tdir/remote_dir
+ local MDTIDX=1
+
+ mkdir -p $DIR/$tdir
+ $LFS mkdir -i $MDTIDX $remote_dir || error "lfs mkdir failed"
+ drop_update_reply $MDTIDX "rm -rf $remote_dir" ||
+ error "rm remote dir failed"
+
+ rm -rf $DIR/$tdir || error "rmdir failed"
+}
+run_test 110f "remove remote directory: drop slave rep"
+
+# LU-2844 mdt prepare fail should not cause umount oops
+test_111 ()
+{
+ [[ $(lustre_version_code $SINGLEMDS) -ge $(version_code 2.3.62) ]] ||
+ { skip "Need MDS version at least 2.3.62"; return 0; }
+
+ local mdsdev=$(mdsdevname ${SINGLEMDS//mds/})
+#define OBD_FAIL_MDS_CHANGELOG_INIT 0x151
+ do_facet $SINGLEMDS lctl set_param fail_loc=0x151
+ stop $SINGLEMDS || error "stop MDS failed"
+ start $SINGLEMDS $mdsdev && error "start MDS should fail"
+ do_facet $SINGLEMDS lctl set_param fail_loc=0
+ start $SINGLEMDS $mdsdev || error "start MDS failed"
+}
+run_test 111 "mdd setup fail should not cause umount oops"
+
complete $SECONDS
check_and_cleanup_lustre
exit_status