#define PRINT_CMD CDEBUG
#include <obd.h>
-#include <lvfs.h>
#include <obd_class.h>
#include <lustre/lustre_user.h>
#include <linux/version.h>
"client and the MGS are running compatible "
"versions of Lustre.\n",
mgc->obd_name, logname, rc);
-
- if (rc)
+ else if (rc != 0)
LCONSOLE_ERROR_MSG(0x15c, "%s: The configuration from log '%s' "
"failed (%d). This may be the result of "
"communication errors between this node and "
GOTO(out_free, rc);
/* Re-using an existing MGC */
- cfs_atomic_inc(&obd->u.cli.cl_mgc_refcount);
+ atomic_inc(&obd->u.cli.cl_mgc_refcount);
/* IR compatibility check, only for clients */
if (lmd_is_client(lsi->lsi_lmd)) {
/* Keep a refcount of servers/clients who started with "mount",
so we know when we can get rid of the mgc. */
- cfs_atomic_set(&obd->u.cli.cl_mgc_refcount, 1);
+ atomic_set(&obd->u.cli.cl_mgc_refcount, 1);
/* Try all connections, but only once. */
recov_bk = 1;
lsi->lsi_mgc = NULL;
mutex_lock(&mgc_start_lock);
- LASSERT(cfs_atomic_read(&obd->u.cli.cl_mgc_refcount) > 0);
- if (!cfs_atomic_dec_and_test(&obd->u.cli.cl_mgc_refcount)) {
+ LASSERT(atomic_read(&obd->u.cli.cl_mgc_refcount) > 0);
+ if (!atomic_dec_and_test(&obd->u.cli.cl_mgc_refcount)) {
/* This is not fatal, every client that stops
will call in here. */
CDEBUG(D_MOUNT, "mgc still has %d references.\n",
- cfs_atomic_read(&obd->u.cli.cl_mgc_refcount));
+ atomic_read(&obd->u.cli.cl_mgc_refcount));
GOTO(out, rc = -EBUSY);
}
lsi->lsi_lmd->lmd_recovery_time_hard = 0;
s2lsi_nocast(sb) = lsi;
/* we take 1 extra ref for our setup */
- cfs_atomic_set(&lsi->lsi_mounts, 1);
+ atomic_set(&lsi->lsi_mounts, 1);
/* Default umount style */
lsi->lsi_flags = LSI_UMOUNT_FAILOVER;
CDEBUG(D_MOUNT, "Freeing lsi %p\n", lsi);
/* someone didn't call server_put_mount. */
- LASSERT(cfs_atomic_read(&lsi->lsi_mounts) == 0);
+ LASSERT(atomic_read(&lsi->lsi_mounts) == 0);
if (lsi->lsi_lmd != NULL) {
if (lsi->lsi_lmd->lmd_dev != NULL)
LASSERT(lsi != NULL);
- CDEBUG(D_MOUNT, "put %p %d\n", sb, cfs_atomic_read(&lsi->lsi_mounts));
- if (cfs_atomic_dec_and_test(&lsi->lsi_mounts)) {
+ CDEBUG(D_MOUNT, "put %p %d\n", sb, atomic_read(&lsi->lsi_mounts));
+ if (atomic_dec_and_test(&lsi->lsi_mounts)) {
if (IS_SERVER(lsi) && lsi->lsi_osd_exp) {
lu_device_put(&lsi->lsi_dt_dev->dd_lu_dev);
lsi->lsi_osd_exp->exp_obd->obd_lvfs_ctxt.dt = NULL;
}
EXPORT_SYMBOL(server_name_is_ost);
-/* Get the index from the obd name.
- rc = server type, or
- rc < 0 on error
- if endptr isn't NULL it is set to end of name */
-int server_name2index(const char *svname, __u32 *idx, const char **endptr)
+/**
+ * Get the index from the target name MDTXXXX/OSTXXXX
+ * rc = server type, or rc < 0 on error
+ **/
+int target_name2index(const char *tgtname, __u32 *idx, const char **endptr)
{
+ const char *dash = tgtname;
unsigned long index;
int rc;
- const char *dash;
-
- /* We use server_name2fsname() just for parsing */
- rc = server_name2fsname(svname, NULL, &dash);
- if (rc != 0)
- return rc;
-
- dash++;
if (strncmp(dash, "MDT", 3) == 0)
rc = LDD_F_SV_TYPE_MDT;
index = simple_strtoul(dash, (char **)endptr, 16);
if (idx != NULL)
*idx = index;
+ return rc;
+}
+EXPORT_SYMBOL(target_name2index);
+
+/* Get the index from the obd name.
+ rc = server type, or
+ rc < 0 on error
+ if endptr isn't NULL it is set to end of name */
+int server_name2index(const char *svname, __u32 *idx, const char **endptr)
+{
+ const char *dash;
+ int rc;
+
+ /* We use server_name2fsname() just for parsing */
+ rc = server_name2fsname(svname, NULL, &dash);
+ if (rc != 0)
+ return rc;
+
+ dash++;
+ rc = target_name2index(dash, idx, endptr);
+ if (rc < 0)
+ return rc;
/* Account for -mdc after index that is possible when specifying mdt */
if (endptr != NULL && strncmp(LUSTRE_MDC_NAME, *endptr + 1,