RETURN(rc);
}
+static inline bool mdc_skip_mod_rpc_slot(const struct lookup_intent *it)
+{
+ if (it != NULL &&
+ (it->it_op == IT_GETATTR || it->it_op == IT_LOOKUP ||
+ it->it_op == IT_READDIR ||
+ (it->it_op == IT_LAYOUT && !(it->it_flags & MDS_FMODE_WRITE))))
+ return true;
+ return false;
+}
+
/* We always reserve enough space in the reply packet for a stripe MD, because
* we don't know in advance the file type. */
static int mdc_enqueue_base(struct obd_export *exp,
__u64 extra_lock_flags)
{
struct obd_device *obddev = class_exp2obd(exp);
- struct ptlrpc_request *req = NULL;
+ struct ptlrpc_request *req;
__u64 flags, saved_flags = extra_lock_flags;
struct ldlm_res_id res_id;
static const union ldlm_policy_data lookup_policy = {
LASSERTF(einfo->ei_type == LDLM_FLOCK, "lock type %d\n",
einfo->ei_type);
res_id.name[3] = LDLM_FLOCK;
+ req = ldlm_enqueue_pack(exp, 0);
} else if (it->it_op & IT_OPEN) {
req = mdc_intent_open_pack(exp, it, op_data, acl_bufsize);
} else if (it->it_op & (IT_GETATTR | IT_LOOKUP)) {
req->rq_sent = ktime_get_real_seconds() + resends;
}
- /* It is important to obtain modify RPC slot first (if applicable), so
- * that threads that are waiting for a modify RPC slot are not polluting
- * our rpcs in flight counter.
- * We do not do flock request limiting, though */
- if (it) {
- mdc_get_mod_rpc_slot(req, it);
- rc = obd_get_request_slot(&obddev->u.cli);
- if (rc != 0) {
- mdc_put_mod_rpc_slot(req, it);
- mdc_clear_replay_flag(req, 0);
- ptlrpc_req_finished(req);
- RETURN(rc);
- }
- }
+ einfo->ei_enq_slot = !mdc_skip_mod_rpc_slot(it);
/* With Data-on-MDT the glimpse callback is needed too.
* It is set here in advance but not in mdc_finish_enqueue()
rc = ldlm_cli_enqueue(exp, &req, einfo, &res_id, policy, &flags, NULL,
0, lvb_type, lockh, 0);
+
if (!it) {
/* For flock requests we immediatelly return without further
delay and let caller deal with the rest, since rest of
(einfo->ei_type == LDLM_FLOCK) &&
(einfo->ei_mode == LCK_NL))
goto resend;
+ ptlrpc_req_finished(req);
RETURN(rc);
}
- obd_put_request_slot(&obddev->u.cli);
- mdc_put_mod_rpc_slot(req, it);
-
if (rc < 0) {
CDEBUG(D_INFO,
"%s: ldlm_cli_enqueue "DFID":"DFID"=%s failed: rc = %d\n",
struct obd_export *exp = ga->ga_exp;
struct md_enqueue_info *minfo = ga->ga_minfo;
struct ldlm_enqueue_info *einfo = &minfo->mi_einfo;
- struct lookup_intent *it;
- struct lustre_handle *lockh;
- struct obd_device *obddev;
- struct ldlm_reply *lockrep;
- __u64 flags = LDLM_FL_HAS_INTENT;
+ struct lookup_intent *it;
+ struct lustre_handle *lockh;
+ struct ldlm_reply *lockrep;
+ __u64 flags = LDLM_FL_HAS_INTENT;
ENTRY;
it = &minfo->mi_it;
lockh = &minfo->mi_lockh;
- obddev = class_exp2obd(exp);
-
- obd_put_request_slot(&obddev->u.cli);
if (OBD_FAIL_CHECK(OBD_FAIL_MDC_GETATTR_ENQUEUE))
rc = -ETIMEDOUT;
struct lookup_intent *it = &minfo->mi_it;
struct ptlrpc_request *req;
struct mdc_getattr_args *ga;
- struct obd_device *obddev = class_exp2obd(exp);
struct ldlm_res_id res_id;
union ldlm_policy_data policy = {
.l_inodebits = { MDS_INODELOCK_LOOKUP |
if (IS_ERR(req))
RETURN(PTR_ERR(req));
- rc = obd_get_request_slot(&obddev->u.cli);
- if (rc != 0) {
- ptlrpc_req_finished(req);
- RETURN(rc);
- }
-
/* With Data-on-MDT the glimpse callback is needed too.
* It is set here in advance but not in mdc_finish_enqueue()
* to avoid possible races. It is safe to have glimpse handler
rc = ldlm_cli_enqueue(exp, &req, &minfo->mi_einfo, &res_id, &policy,
&flags, NULL, 0, LVB_T_NONE, &minfo->mi_lockh, 1);
if (rc < 0) {
- obd_put_request_slot(&obddev->u.cli);
ptlrpc_req_finished(req);
RETURN(rc);
}