run_test 78 "run resize2fs on MDT and OST filesystems"
+test_79() { # LU-4227
+ [[ $(lustre_version_code $SINGLEMDS) -ge $(version_code 2.5.59) ]] ||
+ { skip "Need MDS version at least 2.5.59"; return 0; }
+
+ local mdsdev1=$(mdsdevname 1)
+ local mdsvdev1=$(mdsvdevname 1)
+ local mdsdev2=$(mdsdevname 2)
+ local mdsvdev2=$(mdsvdevname 2)
+ local ostdev1=$(ostdevname 1)
+ local ostvdev1=$(ostvdevname 1)
+ local opts_mds1="$(mkfs_opts mds1 $mdsdev1) --reformat"
+ local opts_mds2="$(mkfs_opts mds2 $mdsdev2) --reformat"
+ local opts_ost1="$(mkfs_opts ost1 $ostdev1) --reformat"
+ local mgsnode_opt
+
+ # remove --mgs/--mgsnode from mkfs.lustre options
+ opts_mds1=$(echo $opts_mds1 | sed -e "s/--mgs//")
+
+ mgsnode_opt=$(echo $opts_mds2 |
+ awk '{ for ( i = 1; i < NF; i++ )
+ if ( $i ~ "--mgsnode" ) { print $i; break } }')
+ [ -n $mgsnode_opt ] &&
+ opts_mds2=$(echo $opts_mds2 | sed -e "s/$mgsnode_opt//")
+
+ mgsnode_opt=$(echo $opts_ost1 |
+ awk '{ for ( i = 1; i < NF; i++ )
+ if ( $i ~ "--mgsnode" ) { print $i; break } }')
+ [ -n $mgsnode_opt ] &&
+ opts_ost1=$(echo $opts_ost1 | sed -e "s/$mgsnode_opt//")
+
+ # -MGS, format a mdt without --mgs option
+ add mds1 $opts_mds1 $mdsdev1 $mdsvdev1 &&
+ error "Must specify --mgs when formatting mdt combined with mgs"
+
+ # +MGS, format a mdt/ost without --mgsnode option
+ add mds1 $(mkfs_opts mds1 $mdsdev1) --reformat $mdsdev1 $mdsvdev1 \
+ > /dev/null || error "start mds1 failed"
+ add mds2 $opts_mds2 $mdsdev2 $mdsvdev2 &&
+ error "Must specify --mgsnode when formatting a mdt"
+ add ost1 $opts_ost1 $ostdev1 $ostvdev2 &&
+ error "Must specify --mgsnode when formatting an ost"
+
+ return 0
+}
+run_test 79 "format MDT/OST without mgs option (should return errors)"
+
test_80() {
start_mds
start_ost
mop.mo_ldd.ldd_flags &= ~LDD_F_NEED_INDEX;
mop.mo_ldd.ldd_svindex = 0;
}
-
-#if 0
- /*
- * Comment out these 2 checks temporarily, since for multi-MDSes
- * in single node only 1 mds node could have mgs service
- */
- if (IS_MDT(ldd) && !IS_MGS(ldd) && (mop.mo_mgs_failnodes == 0)) {
- verrprint("No management node specified, adding MGS to this "
- "MDT\n");
- ldd->ldd_flags |= LDD_F_SV_TYPE_MGS;
- }
- if (!IS_MGS(ldd) && (mop.mo_mgs_failnodes == 0)) {
- fatal();
- if (IS_MDT(ldd))
- fprintf(stderr, "Must specify --mgs or --mgsnode=\n");
- else
- fprintf(stderr, "Must specify --mgsnode=\n");
- ret = EINVAL;
- goto out;
- }
-#endif
+ if (!IS_MGS(ldd) && (mop.mo_mgs_failnodes == 0)) {
+ fatal();
+ if (IS_MDT(ldd))
+ fprintf(stderr, "Must specify --mgs or --mgsnode\n");
+ else
+ fprintf(stderr, "Must specify --mgsnode\n");
+ ret = EINVAL;
+ goto out;
+ }
if ((IS_MDT(ldd) || IS_OST(ldd)) && mop.mo_ldd.ldd_fsname[0] == '\0') {
fatal();